Efeito da água ozonizada durante cirurgia de instalação de implante dentário sobre controle da cicatrização, dor, edema e trismo: ensaio clínico randomizado, boca dividida, triplo cego

dc.contributor.authorSilva, Ângelo Fonseca
dc.contributor.institutionUniversidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)pt_BR
dc.date.accessioned2025-03-21T18:06:12Z
dc.date.issued2024
dc.descriptionBanca de defesa: Glória, José Cristiano Ramos; Corrêa, Gefter Thiago Batista; Souza, Fabrício Tinôco Alvim de; Rocha, Ricardo Lopes (Orientador: Glória, José Cristiano Ramos/Coorientador: Silva, Thiago Fonseca). Data de defesa: 2024-08-02pt_BR
dc.description.abstractA utilização do ozônio tem sido amplamente difundida na área da saúde, uma vez que tal terapia tem demonstrado eficácia no controle de processos inflamatórios e infecciosos ao acelerar os processos de cicatrização. Uma das aplicações da ozonioterapia dentro da área médica é o uso dessa modalidade de tratamento nos processos relacionados às feridas crônicas, como as que ocorrem em pacientes diabéticos e acamados; na Odontologia há estudos demonstrando a eficácia do ozônio nas áreas da Endodontia, Periodontia, Cirurgia e Implantodontia. Apesar dos grandes avanços nos aspectos biomecânicos dos implantes dentários, ainda há uma preocupação em reduzir o desconforto pós-operatório para os pacientes e otimizar o processo de cicatrização inicial dos implantes, fundamental para o sucesso do tratamento. O objetivo deste estudo foi avaliar a utilização da ozonioterapia no controle da dor, edema, trismo e processo cicatricial dos implantes dentários. Para o trabalho, foram selecionados 12 pacientes desdentados posteriores inferiores bilaterais os quais passaram por procedimento cirúrgico de instalação de dois implantes (um do lado direito da mandíbula e outro do lado esquerdo) em duas etapas, com um intervalo de 15 dias entre uma etapa e outra. Por meio da randomização se definiu para cada paciente em qual lado da mandíbula seria instalado o primeiro implante e qual seria a solução irrigadora (água bidestilada ou água bidestilada ozonizada); antes de cada procedimento cirúrgico, foram coletados dos pacientes todos os dados vitais e medidas faciais. Ocorreu ainda a aplicação de questionários no período pós-operatório (com intervalos de 24h, 48h, 72h e 7 dias). Os dados coletados foram tabulados no software SPSS (Statistical Package for the Social Sciences; Chicago; EUA) versão 17.0 for Windows. Foi realizado o teste de Shapiro-Wilk, sendo que as comparações entre os grupos foram feitas por meio de análise de variância (ANOVA) unidirecional ajustada no modelo, seguida do teste Post-Hoc de Bonferroni para comparações múltiplas. O nível de significância adotado foi de 95% (p<0,05). A amostra foi composta, em sua maioria, por pacientes do sexo feminino (N=9), de faixa etária entre 34 e 66 anos. Na mensuração do edema, notou-se seu menor valor nas primeiras 24 horas após- cirurgia (295,69mm) tendo seu pico máximo 48 horas pós-cirurgia (364,74mm). Para o trismo, observou-se sua expressão máxima 48 horas pós-operatórias com uma distância interrincisal de 32,98 milímetros. Para a variável dor, pôde-se verificar que o nível mais alto de dor foi a dor moderada (valores de 4 a 7 registrados na escala de VAS). Observou-se que, nos procedimentos cirúrgicos realizados com a água bidestilada ozonizada, houve redução significativa da dor pós-operatória quando comparada ao grupo controle (p < 0,05). Conclui-se que a água bidestilada ozonizada reduz de forma significativa a dor pós-operatória em cirurgias de implantes unitários.pt_BR
dc.description.abstractsThe use of ozone has been widely disseminated in the healthcare sector, as this therapy has demonstrated effectiveness in controlling inflammatory and infectious processes and accelerating healing processes. One of the applications of ozone therapy within the medical field is the use of this treatment modality in processes related to chronic wounds, such as those that occur in diabetic and bedridden patients; in Dentistry, there are studies demonstrating the effectiveness of ozone in the areas of Endodontics, Periodontics, Surgery and Implantology. Despite major advances in the biomechanical aspects of dental implants, there is still a concern about reducing post-operative discomfort for patients and optimizing the initial healing process of the implants, which is essential for the success of the treatment. The objective of this study was to evaluate the use of ozone therapy in controlling pain, edema, trismus and the healing process of dental implants. For the study, 12 bilateral lower posterior edentulous patients were selected, who underwent a surgical procedure to install two implants (one on the right side of the jaw and the other on the left side) in two stages, with an interval of 15 days between one stage and the next. ; through randomization, it was defined for each patient on which side of the jaw the first implant was installed and what the irrigating solution would be (double-distilled water or ozonized double-distilled water); Before each surgical procedure, all vital data, facial measurements and questionnaires were collected from the patients. This approach was also adopted in the post-operative period (at intervals of 24 hours, 48 hours, 72 hours, and 7 days). The data were tabulated in the SPSS software (Statistical Package for the Social Sciences; Chicago; USA) version 17.0 for Windows, the Shapiro-Wilk test was performed, comparisons between groups were made using analysis of variance (ANOVA) one-way adjusted in the model, followed by the Bonferroni Post-Hoc test for multiple comparisons. The significance level adopted was 95% (p<0.05). The sample was mostly composed of female patients (N=9), aged between 34 and 66 years. When measuring edema, its lowest value was noted in the first 24 hours after surgery (295.69mm), with its maximum peak 48 hours after surgery (364.74mm). For trismus, its maximum expression was bserved 48 hours postoperatively with an interincisal distance of 32.98 millimeters. For the pain variable, the higher level of pain was moderate pain (values from 4 to 7 recorded on the VAS scale). It was observed that in surgical procedures performed with ozonized double-distilled water there was a significant reduction in postoperative period when compared to the control group (p < 0.05). It is concluded that ozonized double-distilled water significantly reduces postoperative pain in single implant surgeries.en
dc.description.thesisTese (Doutorado) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2024.pt_BR
dc.identifier.citationSILVA, Ângelo Fonseca. Efeito da água ozonizada durante cirurgia de instalação de implante dentário sobre controle da cicatrização, dor, edema e trismo: ensaio clínico randomizado, boca dividida, triplo cego. 2024. 51 p. Tese (Doutorado em Odontologia) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2024.pt_BR
dc.identifier.urihttp://localhost:4000/handle/123456789/3571
dc.language.isopt
dc.publisherUFVJMpt_BR
dc.rightsOpen Accessen
dc.rightsAttribution-NonCommercial-NoDerivs 4.0 Brazilen
dc.rights.licenseA concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data.pt_BR
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.pt
dc.subjectImplante dentário
dc.subjectOzonioterapia
dc.subjectDor
dc.subjectEdema
dc.subjectTrismo
dc.subjectDental implant
dc.subjectOzone therapy
dc.subjectPain
dc.subjectTrismos.
dc.titleEfeito da água ozonizada durante cirurgia de instalação de implante dentário sobre controle da cicatrização, dor, edema e trismo: ensaio clínico randomizado, boca dividida, triplo cegopt_BR
dc.typeThesisen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
angelo_fonseca_silva.pdf
Size:
2.57 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: