Proposta de dimensionamento de unidade de destinação e avaliação da toxicidade de lodo: estudo de caso na Estação de Tratamento de Água Seminário em Mariana/MG

dc.contributor.authorAguilar, Núbia Aparecida de
dc.contributor.institutionUniversidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)pt_BR
dc.date.accessioned2025-03-24T21:16:13Z
dc.date.issued2024
dc.descriptionBanca de defesa: Franco, Elton Santos; Rodrigues, Jairo Lisboa; Dutra, Tuane de Oliveira; Lima, Fernando Neves; Hilário, Ronderson Queiroz; Costa, Alexandre Sylvio Vieira da (Orientador: Franco, Elton Santos/Coorientador: Rodrigues, Jairo Lisboa). Data da defesa: 2024-06-05pt_BR
dc.descriptionO orientador e coorientador do trabalho não mencionados na lista da Folha de Aprovação.pt_BR
dc.description.abstractAs Estações de Tratamento de Água (ETA) utilizam processos e operações para tornar a água bruta adequada para o consumo humano. Durante a etapa de decantação, tem-se a geração de lodo, que, classificado como resíduo sólido e com potencial tóxico, não é permitido o seu lançamento em águas superficiais. Dentro do contexto, o presente estudo teve como objetivo quantificar o lodo, otimizar uma Unidade de Tratamento de Resíduos (UTR) para a ETA Seminário, localizada em Mariana/MG e avaliar a sua toxicidade. Para a quantificação e dimensionamento da UTR equações empíricas encontradas na literatura foram utilizadas. A avaliação foi através de bioensaio de Allium Cepa (sementes de cebola), com citotoxicidade pelo Índice Mitótico das células e a genotoxicidade conforme as aberrações cromossômicas. O teste estatístico t de student não paramétrico, com nível de significância menor ou igual a 0.05, foi utilizado para otimização dos resultados. As equações desenvolvidas para a estação em estudo, que utilizam a dose do coagulante como parâmetro, forneceram uma estimativa mais precisa da produção de lodo em comparação com as outras equações utilizadas. O ano de 2018 apresentou maior produção e foi utilizado para o dimensionamento da UTR composta por 3 leitos de secagem com área de 24 m2. Os resultados de citotoxicidade apresentaram IM significativos, já a genotoxicidade também apresentou nível de aberrações significativas, encontrando alterações como C-metáfase, ponte em anáfase e telófase, mostrando que o lodo em estudo pode apresentar toxicidade. Há poucos estudos sobre bioensaios com Allium cepa para lodo de ETA, recomenda-se a realização de outros ensaios como mutagenicidade. Ademais, análises físico-químicas, para que, dependendo dos resultados, o resíduo possa ser utilizado como matéria-prima para a produção de cerâmicas, carvão ativado e outras aplicações.pt_BR
dc.description.abstractsWater Treatment Plants (WTP) use processes and operations to make raw water suitable for human consumption. During the sedimentation stage, sludge is generated, which is classified as a solid waste with potential toxicity, and its discharge into surface waters is not permitted. In this context, the present study aimed to quantify the sludge, optimize a Waste Treatment Unit (WTU) for the Seminário WTP, located in Mariana/MG, and evaluate its toxicity. Empirical equations found in the literature were used for quantification and sizing of the WTU. The evaluation was conducted through a bioassay using Allium cepa (onion seeds), assessing cytotoxicity by the Mitotic Index of the cells and genotoxicity based on chromosomal aberrations. The non-parametric Student's t-test, with a significance level of 0.05 or less, was used to optimize the results. The equations developed for the studied station, which use the coagulant dose as a parameter, provided a more accurate estimate of sludge production compared to the other equations used. The year 2018 showed the highest production and was used for sizing the WTU, which consisted of 3 drying beds with an area of 24 m2 each. The cytotoxicity results showed significant Mitotic Indexes, while genotoxicity also showed significant levels of aberrations, including C-metaphase, anaphase bridge, and telophase, indicating that the sludge under study may exhibit toxicity. There are few studies on Allium cepa bioassays for WTP sludge, further assays, such as mutagenicity tests, are recommended. Additionally, physical-chemical analyses are suggested so that, depending on the results, the residue could potentially be used as a raw material for producing ceramics, activated carbon, and other applications.en
dc.description.thesisDissertação (Mestrado Profissional) – Programa de Pós-Graduação em Tecnologia, Ambiente e Sociedade, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2024.pt_BR
dc.identifier.citationAGUILAR, Núbia Aparecida de. Proposta de dimensionamento de unidade de destinação e avaliação da toxicidade de lodo: estudo de caso na Estação de Tratamento de Água Seminário em Mariana/MG. 2024. 49 p. Dissertação (Mestrado Profissional em Tecnologia, Ambiente e Sociedade) – Programa de Pós-Graduação em Tecnologia, Ambiente e Sociedade, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Teófilo Otoni, 2024.pt_BR
dc.identifier.urihttp://localhost:4000/handle/123456789/3579
dc.language.isopor
dc.publisherUFVJMpt_BR
dc.rightsOpen Accessen
dc.rightsAttribution-NonCommercial-NoDerivs 4.0 Brazilen
dc.rights.licenseA concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data.pt_BR
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.pt
dc.subjectResíduos sólidos
dc.subjectUnidade de tratamento de resíduos
dc.subjectAllium Cepa
dc.subjectCitotoxicidade
dc.subjectGenotoxicidade
dc.subjectSolid waste
dc.subjectWaste treatment unid
dc.subjectCytotoxicity
dc.subjectGenotoxicity.
dc.titleProposta de dimensionamento de unidade de destinação e avaliação da toxicidade de lodo: estudo de caso na Estação de Tratamento de Água Seminário em Mariana/MGpt_BR
dc.typeThesisen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nubia_aparecida_aguilar.pdf
Size:
1.13 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: